Magnetic Fluid
Conditioner
For 1" to 2" Tubing or Pipe.
Single Device - Magnetic Water Softener
SALE Price $199.99!
Discontinued Model Only
APPLICATIONS
Primary
Applications:
Swimming Pools, spas, residential,
commercial, agricultural and industrial applications wherever hard
water is present (plumbing systems, appliances, pools,
and spas).
Other
applications: systems for apartment, and condominiums,
water-cooled equipment, laundries, car washes,irrigation
systems.
INSTALLATION
Installation
for 1" Pipe
1-1/2" for Manual Feed,
(Up to 2" on Recirculating Systems)
Use this
installation procedure to install two Model 848 units on
1" pipes, or on 1-1/2" pool and spa plumbing (recirculated
water).
1. Place
the Model 848 unit against the pipe or tube, with the
label facing away from the pipe.
2. Place
the backing plate on the opposite side of the pipe. Align
the holes in the backing plate with the holes in the unit.
3. Insert
bolts through the holes in the unit and the backing plate.
Secure with wing-nuts.
4. Tighten
the unit until it is snug against the pipe. Do not over-tighten!
5. Install
the second unit in tandem with the first. Leave 1"
space between them. Make sure the labels of both units
are on the same side and face the same direction.
SPECIAL NOTES
Placement:
The Model
848 is designed to be placed wherever the water line
enters the building, or at least 8"or 12"
upstream(before) any specific area or appliance to be
treated.
For pools
and spas, place the Model 848 downstream (after) all
equipment (usually the heater) on the return line before
the pool.
Direction
of Placement:
The magnet
above the label is the north pole, and the magnet
below the label is the south pole. The direction the
fluid flows through the pipe or tubing makes no
difference.
For best
results when placing the Model 848 to treat a particular
area or appliance, place the segments at least 8" or
12" upstream (before) the area or appliance to be
treated.
Do not
place the Model 848 close to an electrical power line, or
electrical equipment capable of generating strong
electrical fields,such as a welder or large electrical
motor. This can reduce the units' effectiveness.
For
maximum effectiveness magnetic conditioning requires a
smooth, calm, flow of fluid through the magnetic field. A
partial reversal of the treatment may even be triggered
by turbulence. Therefore, always place the Model 848 a
minimum of 18" to 24" downstream (after) any
pump or other turbulence -causing device.
Non
Ferrous Pipes Only:
Install
the Model 848 units only on non-ferrous (PVC,
Plastic,copper,or stainless steel) pipe or tubing --not
on steel or iron pipe. Don't place them on any pipe to
which the magnets stick. The penetration through iron or
steel (except for stainless steel ) pipe is minimal. In
effect, the magnetic field travels along the exterior of
the pipes, preventing it from reaching the fluid. In such
cases replace an 18" to 24" section of steel
pipe ,with either copper or PVC pipe and then install the
Model 848 on that section.
Stabilization
Period:
For a few
weeks after installing the Model 848 you may notice an
increase in water turbidity(cloudiness). This is because
scale is being removed from the system. During this
stabilization period, carefully monitor filters, tanks,
and sumps each week, and drain or clean them as needed.
Magnetic Fluid
Conditioner
For 2" to 8" Tubing or Pipe.
1 Set (2 devices) - Industrial Conditioner
SALE Price $479.99!
Discontinued Model Only
APPLICATIONS
Primary
Applications:
Residential,
Commercial, Industrial,and agricultural applications
wherever hard water is present.
INSTALLATION
PLEASE
NOTE:
Each Model
8000 set consists of two separate pieces. One piece has
two north pole magnets. This is the side covered by the label. The other piece has two south pole magnets. A
system consists of one or two sets, held to the pipe by a
common band. There should always be a 1"space
between units.
Installation
on 2" to 4" Pipe:
Install
two sets in two units 1" apart . The sets must be
placed so that the north pole pieces are lined up with
each other on the same side of the pipe, and the south
pole pieces are in line with each other on the exact
opposite side of the pipe.
Installation
on 5" to 6" Pipe:
Install
three sets in three units 1" apart. The sets must be
placed so that the north pole pieces are lined up with
each other on the same side of the pipe,and the south
pole pieces are in line with each other on the exact
opposite side of the pipe.
Installation
on Over 6" to 8" Pipe:
Install
six sets in three units with two sets in each units. The
north pole pieces of both sets in each unit must be
placed side-by-side on one side of the pipe. The south
pole pieces of both sets in each unit must be placed side-by-side
on the opposite side of the pipe. (For example, if the
two north pole pieces in the unit were placed at the 11:00
and 1:00 positions, then the two south pole pieces would
be placed at the 5:00 and 7:00 positions.)
PROCEDURE FOR INSTALLATION
1. Position
the Model 8000 units according to the preceding
instructions.
2. Hold
the units into position with fiberglass tape before
installing the steel banding.
3. Hold
the "rack" that comes with the steel banding so
that the words " This Side Up" are facing you.
Insert the end of the rack into the screw housing and
turn the screw just enough to engage the rack.
4. Bend
the end of the steel band toward the underside to form a
hook. Insert this into the band slot in the housing.
5. Wrap
the band snugly around the units.
6. Make
a second bend [hook] 1" past the band slot in the
rack. Secure the band ends behind the units.
7. Insert
the hook into the band slot in the rack and flatten it to
form the clamp. Any excess band must be folded back under
the unit, or can be trimmed off. Tighten the screw with a
screwdriver to the desired tension.
8. Carefully
check the units to make sure they are firmly secured to
the pipe before removing the tape.
SPECIAL
NOTES
Use
Caution:
The Model
8000 sets are heavy and can cause injury or damage if
dropped. Before clamping them into place with the steel
bands, secure the sets in place with fiberglass strapping
tape.
Placement:
The
direction the fluid flows through the pipe on which the
units are installed makes no difference.
For best
results when placing the Model 8000 to treat a particular
area or appliance, place the units at least 8" to 12"
upstream (before) the area or appliance to be treated.
Do not
place the Model 8000 close to an electrical power line,
or electrical equipment capable of generating strong
electrical fields, such as a welder or large electrical
motor. This can reduce the unit's effectiveness.
For
maximum effectiveness magnetic fluid conditioning
requires a smooth, calm, flow of fluid through the
magnetic field. A partial of the treatment may even be
triggered by turbulence. Therefore, always place the
Model 8000 a minimum of 24"downstream (after) any
pump or other turbulence-causing device.
Non-Ferrous
Pipes Only:
Install
the Model 8000 only on non-ferrous (PVC, plastic,
copper,or stainless steel) pipe or tubing--not on steel
or iron pipe. Don't place it on any pipe to which the
magnets stick. The penetration of the magnetic field
through iron or steel (except for stainless steel) pipe
is minimal. In effect, the magnetic field travels along
the exterior of such pipes preventing it from reaching
the fluid. In such cases, replace and 18" to 24"
section of steel pipe with either copper or PVC pipe, and
then install the Model 8000 on that section.
Stabilization
Period:
For a few
weeks after installing the Model 8000 you may notice and
increase in water turbidity (cloudiness). This is because
scale is being removed from the system. During this
stabilization period, carefully monitor filters, tanks,
and sumps each week, and drain or clean them as needed.
Scale and Calcium buildup within pipes.

Incomplete combustion results in harmful
emissions, as well as decreased fuel efficiency and engine performance.
Like scale build-up in water, these problems take dollars out of your
pocket and harm the environment.
We have created magnetic fluid
conditioning devices that capture the full power of
magnetohydrodynamics and put it to work for you.
It begins with the magnets themselves.
The heart of all products are super high-powered ceramic magnets.
Originally developed by the U.S. government for NASA's Space Program,
these high-tech, lightweight, compact magnets pack thousands of gauss
of magnetic pull into a small space. And they don't wear out or require
outside power! In fact, over a normal human life span, the magnets lose
an insignificant amount of their original strength! While the basic
technology has been used for many years in industrial applications, the
compact new magnets allow the advantages of magnetic fluid
conditioning to go into private residences...even cars and trucks.
"The potential benefits which
could be derived from a non-chemical method of water conditioning of
this type (magnetic fluid conditioning) include reduced energy
requirements, water conservation, reduction or elimination of chemical
feed and control requirements, and reduced pollution."
American Petroleum Institute, Washington D.C.
Evaluation of the Principles of Magnetic Water Treatment
API Publication 960, September, 1985
"Old ways die hard but the change is inevitable. We stand on the threshold of a magnetic revolution in fluid conditioning."
Dennis Sheppard & Ron Van Dyke,
Clash of Technologies, January 1993
"No
one argues whether magnetic treatment is effective or not: in the
Soviet Union the magnetic treatment of water is used extensively and
with tremendous economic effect."
V.I. Klassen Ph.D., Institute of Mineral Fuels,
Academy of Sciences, USSR, 1969
But
the magnet isn't everything. Unless magnetic fluid conditioning devices
are designed to take advantage of the principles of
magnetohydrodynamics, they are worthless. The products of --- the
leader in this technology --- are not only properly designed, they are
designed better than any other products of their kind.
There are three reasons for this:
1. Contact time
The
amount of time a fluid is in contact with the magnetic field as it runs
through a pipe is called "contact time." The amount of contact time is
indicated by the length of pipe that is exposed to the magnetic field.
The more contact time, the more effective the conditioning. Some
magnetic fluid conditioners give the fluids only a half-inch of contact
time. That's a major difference.
2. Focus
The
focus of the energy field is another essential factor. A magnetic fluid
conditioning unit must be focused properly on the fluid that runs
through the pipe. If the water or fuel is not squarely within the focal
range.
3. The Magnet's Strength
All magnetic fluid conditioning products are made with grade 8 ceramic
magnets developed by NASA. Ceramic magnets are the only material known
to man to hold a permanent magnetic charge throughout a human's
lifetime. In 125 years, these lose less than 3 percent of their power.

1. Typical scale and calcium buildup caused by untreated water has almost closed this pipe.

2. This photo shows the effect of magnetically treated water on the same section of pipe a short time after the installation.

3. After continual treatment, most scale is removed and will be prevented as long as the system is in operation.